US $19.97

ETAP Power System Protection Analysis

——   Created by Elektrik Power Academy

The Complete Protection and Coordination Course in ETAP Software For Electrical Engineers

Share this course:

NEW
Course
13
Lessons
3h 09m
Lesson time
all
Skill levels

More about this course

"Want To Become Expert In ETAP Software and Power System Protection in ETAP?" This course will help you to achieve your goals to become Power System Protection Expert in ETAP .

Welcome to the course "ETAP Power System Protection Analysis"

ETAP is an analytical engineering software which is helpful for an electrical engineer to simulate and analyze the steady state and dynamic power system. It is used by various sectors such as Generation, Transmission, Distribution, Industrial, Transportation and Low voltage.

The purpose of this course is to learn power system modeling & power system protection analysis using ETAP software which will cover a range of ETAP functionalities used to design & solve various power system protection practical problems.

The course will begin with the basics of one-line diagram creation with respect to protection and coordination analysis, data entry, and quickly expands the users’ knowledge to include methods to automatically perform the protection and coordination analysis of electrical system. Wherever possible, the topics are explained with hand calculations and results are compared with ETAP software so that it becomes more easier to the attendees to understand the concepts.

The purpose of the protection coordination study is to verify that the various protection devices such as relays, breakers, fuses etc in the electrical system, are coordinated correctly and are sized appropriately for the equipment that they are protecting.

Major Topics Covered In The Course:

  • Overcurrent and Earth Fault Protection and Coordination Analysis Fundamentals
  • Overcurrent and Earth Fault Protection and Coordination Analysis Example
  • Automated Protection and Coordination (Star Auto-Evaluation)
  • Understanding of CT Polarity
  • Ring Main System Coordination Fundamental
  • Ring Main System Coordination Example
  • Protection and Coordination of Parallel Multiple Sources Fundamentals and Example
  • Voltage Dependent Relay Coordination Fundamentals For Generator
  • Voltage Dependent Relay Coordination Example For Generator

13 Lessons

8 mins
Protection System Protection Course Introduction
free preview
23 mins
Protection & Coordination Analysis Fundamentals
53 mins
Protection & Coordination Analysis Example (For Radial System)
13 mins
Automated Protection and Coordination Example (ETAP Star-Auto Evaluation)
free preview
3 mins
Understanding of Current Transformer (CT) Polarity
15 mins
Ring Main System Coordination Fundamentals
6 mins
Ring Main System Coordination Example
8 mins
Relay Coordination for Multiple Parallel Source - Fundamentals
12 mins
Relay Coordination for Multiple Parallel Sources- Method1 - ETAP Example
8 mins
Relay Coordination for Multiple Parallel Sources- Method2 - ETAP Example
6 mins
Relay Coordination for Multiple Parallel Sources- Method3 - ETAP Example
13 mins
Voltage Dependent Protection and Coordination Fundamentals
28 mins
Voltage Dependent Protection and Coordination - ETAP Example

About the instructor

Elektrik Power Academy

I am an Electrical Engineer and a Free Lancer having rich experience in power system analysis, substation & switchyard design and engineering and in power …

Read more
This course is included in Arbington Premium
$15/month gets you access to every course. Start your 14 day trial today. ☝️

Class benefits

  • Certificate of Completion
  • 30 day satisfaction guarantee
  • 24/7 streaming access
  • Direct teacher access
  • 3h 09m of on-demand video
  • 2 downloadable files
  • Have a coupon?
  • Checkout